XLOAD SPECIFICATIONS

XLOAD Product
Measurement CapabilitySpecs
Maximum Range4 m (157.5″)
Resolution – Displacement2 mm (0.08″)
Total Measurement Error± 10 mm (0.59″) (In lab)
Radar FrequencyK – Band
EnvironmenalSpecs
Process Temperature-40°C to +85°C (-40°F to +185°F)
Operational Temperature-40°C to +85°C (-40°F to +185°F)
Storage Temperature-40°C to +85°C (-40°F to +185°F)
IP RatingIP67
Flange Mount104.8 mm (4.125″) or 82.6 mm (3.25″) B.C. w/ 50.8 mm (2″) gasket
Dimensions114.3 mm (4.5″) diam x 215.9 mm (8.5″) tall
Mass4.1 kg (9.04 lbs)
Vibration6 g RMS 10-2000Hz
Shock100 g Half Sine 2ms any direction
Max Operating Pressure448 kPa (65 psi)
Minimum Burst Pressure> 300 psi
Pending Certifications